PRODUCTS

BTM Shingle Yonca

BTM Shingle Yonca is a fibreglass-reinforced roof covering and waterproofing membrane made of oxidated bitumen, which is coated with sand on the lower surface and by coloured mineral granules on the upper surface.

ADVANTAGES
  • It is waterproof.
  • It is easy to apply.
  • Available in colors that match every building.
  • It is light and does not burden your roof.
  • It is extremely wind resistant.
  • It is long lasting.
  • It is resistant to UV rays.

PLACES OF USE
  • For roof covering and waterproofing purposes on sloping roofs,(The minimum recommended slope is 20%.)
  • on sloping pergolas.

SURFACE PREPARATION

Please see the Shingle Application Guide or the application information on the packaging.


APPLICATION

Please see the Shingle Application Guide or the application information on the packaging.

Ventilation:

An appropriate ventilation system should be provided in order to prevent premature failure of the roofing including blistering, buckling of the roofing shingles due to deck movement. If implemented correctly, proper ventilation methods can help ensure the maximum service life of roof assembly materials. It is recommended a minimum of at least 1 square metre of attic ventilation (both intake and exhaust) for every 300 square metres of attic space. This amount should be divided equally between intake and exhaust ventilation to insure proper air flow through the attic. Two types of exhaust vents are available; one with cap, other without cap. One exhaust vent for every 10 square metre of attic space to be installed near the ridge, for a proper ventilation. Also, proper intake space along eaves should be provided with bird and insect netting. BTM A.S. can not be held responsible for any damages on shingled roofs caused by inappropriate or no attic ventilation.  

Warnings:

Shingle packages should be protected from low & high temperatures and moisture before use.
The roofing materials (OSB, water plywood) to be Shingle covered should be dry.
OSB panel end joints must be staggered and a minumum of 3 mm of expansion gap must be left in all edges, in order to prevent shingle layer from substrate movement. BTM A.S. can not be held responsible for any damages on shingled roofs caused by inappropriately constructed decks.
An appropriate ventilation system should be provided in order not let roof temperature increase.


PACKAGING

BTM Shingle Clover sheets are 33 cm wide and 100 cm long.

BTM Shingle Yonca is launched into the market in packs. A pack contains 21 sheets, and 21 sheets are good to cover 2,94 m 2 of finished surface.


STORAGE CONDITION AND SHELFLIFE

Packs must be stored in roofed-over spaces. They must be stored not more than three packs one on top of the other and out of the sunlight.


Important note:

Please ask to see a product sample before making the final decision on your color and model selection. Screen view and catalog print images may differ from the actual product for technical reasons. 
For this reason, BTM cannot be held responsible for differences such as color, shade and texture.

 adres_2BTM Bitümlü Tecrit Maddeleri Sanayi ve Ticaret A.Ş. Kemalpaşa O.S.B. Mahallesi Gazi Bulvarı No:152 35730 Kemalpaşa/İzmir TURKEY Phone:+90 232 877 04 02 Fax:+90 232 877 04 10  info@btm.co • www.btm.co


MANAGEMENT SYSTEM DOCUMENTS
ISO 9001-2015 Quality Management System Certificate
aNVNn